NodeLoop

Differential Pair Skew & Length Matching

Turn a length mismatch into a delay skew, compare it with your timing budget, and see how much length to add to the shorter trace.

Input Parameters

ps/mm

The Controlled Impedance Designer gives this value for your real geometry.

mm
mm
ps

Delay Skew

-- ps

Delay used: --

Length mismatch: --

Allowed mismatch for the budget: --

Differential Pair Lengths Visual representation of the two trace lengths. A: 10 mm B: 10 mm

How It Works

Delay per unit length is √εeff/c, about 3.34 ps/mm × √εeff. In a stripline εeff = εr (about 6.9 ps/mm for εr = 4.3). In a microstrip the field is partly in air, so εeff lies between (εr+1)/2 and εr, and depends on width, height and solder mask. Without a delay value the tool uses (εr+1)/2, which underestimates the delay by roughly 10 % on typical FR-4 geometries; enter the ps/mm value from your stackup instead.

Example: a 0.8 mm mismatch at 6.0 ps/mm gives 4.8 ps of skew. With a 5 ps budget, the allowed mismatch is 5 / 6.0 ≈ 0.83 mm, so this pair just fits.

The budget itself comes from the interface (setup/hold margin, or intra-pair skew limits in its specification or your SerDes datasheet); a generic number does not certify a link. Vias, connectors, package pins and fibre-weave effects add skew that the drawn length does not show, so keep margin.