Differential Pair Skew & Length Matching
Turn a length mismatch into a delay skew, compare it with your timing budget, and see how much length to add to the shorter trace.
Input Parameters
The Controlled Impedance Designer gives this value for your real geometry.
Delay Skew
-- ps
Delay used: --
Length mismatch: --
Allowed mismatch for the budget: --
How It Works
Delay per unit length is √εeff/c, about 3.34 ps/mm × √εeff. In a stripline εeff = εr (about 6.9 ps/mm for εr = 4.3). In a microstrip the field is partly in air, so εeff lies between (εr+1)/2 and εr, and depends on width, height and solder mask. Without a delay value the tool uses (εr+1)/2, which underestimates the delay by roughly 10 % on typical FR-4 geometries; enter the ps/mm value from your stackup instead.
Example: a 0.8 mm mismatch at 6.0 ps/mm gives 4.8 ps of skew. With a 5 ps budget, the allowed mismatch is 5 / 6.0 ≈ 0.83 mm, so this pair just fits.
The budget itself comes from the interface (setup/hold margin, or intra-pair skew limits in its specification or your SerDes datasheet); a generic number does not certify a link. Vias, connectors, package pins and fibre-weave effects add skew that the drawn length does not show, so keep margin.